99在线免费观看-99在线免费观看视频-99在线免费视频-99在线热播-99在线热播精品免费-99在线热视频

Product

ULTRASONIC FLAW DETECTOR UT500B

ULTRASONIC FLAW DETECTOR UT500B

Product Overview

Based on ultrasonic principle, digital ultrasonic flaw detector UT500B with 320*240 TFT LCD, it can test, orient, evaluate and diagnose various flaws such as crack, lard, air hole in workpiece’s interior swiftly and accurately without any destruction. It can be used in Laboratory as well as in engineering filed. With range of 0-9999mm, it can meet the requirement for general defect inspection in manufacturing industry, metallurgical industry, metal processing industry, chemical industry and so on. Low power design with large capacity and high performance lithium battery module, it can be long standby for months. High quality with low price, it is the first choice for the practical economic model for ultrasonic testing equipment.

Technical Parameters

Measuring Range: (0 ~9999) mm in steel

Bandwidth: 0.5 to 15MHz automatic matching according to the probe frequency.

Material Velocity: (1000 ~ 9999) m / s

Dynamic Range:  36dB

Vertical Linear Error: 3.0%

Horizontal Linear Error: 0.2%

Resolution: > 40dB (5P14)

Sensitivity Leavings: >60dB (flat-bottomed deep hole 200mmФ2)

Rejection: (0 to 80)% Linear without affecting the linearity and gain.

Noise Level: 10%

Probe Type: Straight beam probe, angle beam probe, dual element probe, through-transmit probe.

Gates: Wave-getting Gate, Wave-losing Gate, Single Gate Reading, Dual Gate Reading.

Alarm: Beep Alarm and LED light Alarm.

Power Supply: DC 9V

Working Time: 8 hours

Overall Dimensions: 263 × 170 × 61(mm)

Operating Temperature: (-10 ~ 50)

Relative Humidity: (20 ~ 95)% RH

Pulse Energy: Low(300V), Medium(500V) and High(700V) selectable, suitable for various probe

Pulse Width: (0.10.512)μs range with continuous adjustment to match the different frequency probes

Probe Damping: 100Ω, 200Ω、400Ω selectable to meet different requirements for resolution and sensitivity.

Sampling: 10 digits AD Converter at the sampling speed of 160MHz, waveform of highly fidelity.

Rectification: Positive half wave, negative half wave, full wave, RF.

Gate Reading: Optional for single gate and double gate reading mode, peak readings within the gate

Gain: 0 dB to 110 dB adjustable in selectable steps 0.1 dB, 1 dB, 2dB and 6dB.

Probe Connections: BNC or LEMO

Features

Gate Alarm

Gate position, gate width and gate height can be adjustable at will. The B gate can chose to set wave-getting alarm or wave-losing alarm. The beep in gate and LED light can be alarmed or closed (the LED light alarm is very effective under the noise environment).  

Data Storage

The instrument is built with mass storage. The data and files will not be lost because of instrument power breakdown. The storage contents included channel parameters, waveform pictures and video files. It supports 100 groups of flaw detecting parameters channels. It can preset well for the combination parameters of various types of probes and instruments as well as set testing standards for each industry freely. It can save 10000 pictures of detecting echo signals and parameters. It can realize to save, read and transfer the data via the USB port. 

Video Function

The instrument supports for saving the inspection process as video file and save it to the internal storage card. Video file can be replayed through the instrument. The instrument can support 2 minutes video.

Real-Time Clock

Record and save the tracking record of detecting date and time in real time

Communication

With USB2.0 high speed communication interface, It also can use special software to upload and download data through the USB port.

Battery Module

The large capacity lithium battery module is easy to be assembled and disassembled. It can be charged independently but also charged by inserting wire. Its continuously working time is more than 8 hours

Flaw Detecting Function

Flaw Detecting Standard: Built-in the commonly used flaw detecting standards for each industry. It can be directly called for using convenient and fast.

Welding Figure: It can set the weld parameters, show the welding figure and defects as well as echo path directly during testing.

Automatic Calibration: Automatic calibration for P-Delay and probe angle (K value), automatic measuring function for sound velocity.

Peak Memory: real-time search the defect with highest wave and record the defect peak echo.

Defect Positioning: real-time display the defect level, depth (vertical) and sound path position.

Defect quantify: real-time display the defect equivalent dB value

Defect quality: With echo envelope waveform, it is convenient for judging according to artificial experience.

Curved Surface Correction: Used for flaw detecting for the curved surface workpiece, it can display the defect circumferential position and depth in real time.

Digital-analogy dual-use: without needing do AVG curve, using the bottom wave gain method to measure dB value to achieve the dual-use for digital-analogy, it is easy to operate.

ΦValue Calculation: It can auto-calculate and display the defects equivalent size after finding the peak echo of defect when the straight probe detecting to the forgings.

DAC/AVG: Automatic produced curves without limitation for sampling point, it can do offset and correction for the curves. The curves float automatic with the gain and expand automatic with sound path as well as move automatic with time delay. It can show any aperture AVG curve.

Gain: 0 dB to 110 dB adjustable in selectable steps 0.1 dB, 1 dB, 2dB and 6dB. Unique automatic gain adjustment and scanning gain function make the flaw detecting fast and accurate.

AWS D1.1/1.5: The American Welding Society standard provides a dynamic reflector "defect level” for all types AWS weld inspection applications. It can avoid manual calculation and improve the detection efficiency.

Crack Depth: with endpoint diffraction wave, it can measure and calculate the crack depth automatically.

Envelope in Gate: Amplify the echo details, easy for echo analysis

Continuous Record: real-time record the waveform, save and playback it.

Waveform freeze: freeze the waveform showed on the screen for conveniently analysis the defect.

Echo Code: Display 1-6 times echo display area in different colors, distinguish the first and second wave better, easy to determine the defect position.

Common B Scan: real-time scanning, cross section display,make the detecting result more visually.

Configuration


No.

Item

Qty

Remarks

Standard

 config.

1

Main unit

1


2

Straight Beam Probe

1

4 MHz, Φ10

3

Angle Beam Probe

1

4 MHz, 8 mm×9 mm, 60°

4

Probe Cable

1

BNC-LEMO00

5

Battery Module

1

or LEMO01-LEMO00

6

Power Adapter

1

MB-02

7

Power Cable

1


8

Instrument Case

1


9

Support pillar

1


10

Data Proceeding Software

1


11

USB Communication Cable

1


12

Manual



13

Product Certificate



14

Warranty Card



15

Packing List

1


Optional config.

1

Protective Cover for Main Unit



2

Various Probes



3

Various Probe Cables



 
主站蜘蛛池模板: 色噜噜狠狠成人中文小说 | 97国产在线观看 | 波多野结衣免费免费视频一区 | 欧美日本在线播放 | 在线手机福利免费福利院 | 奇米999| 97se亚洲综合自在线尤物 | 日本高清中文字幕一区二区三区 | 亚洲一区二区三区不卡在线播放 | 亚洲精品一区二区不卡 | 免费看欧美一级特黄a毛片 免费看欧美一级特黄α大片 | 高清在线亚洲精品国产二区 | 亚欧毛片 | 伊人成年综合网 | 国产亚洲精品久久 | 秋霞在线观看成人高清视频51 | 在线观看国产一区二三区 | 亚洲欧洲一区二区三区久久 | 在线看片黄色 | 久久艹在线观看 | 欧美日韩国产成人综合在线 | 色视频在线播放 | 无毒不卡 | 国产精品视频第一页 | 香蕉视频网站免费观视频 | 国产成人无精品久久久久国语 | 5060网永久免费一级毛片 | www.亚洲在线 | 国产精品久久久久毛片 | 一级成人毛片免费观看欧美 | 成 人 黄 色 视频播放1 | 亚洲欧美国产高清va在线播放 | 久久免费精彩视频 | 国产一级视频久久 | 婷婷国产偷v国产偷v亚洲 | 妖精视频永久在线入口 | 久久99精品久久久久久园产越南 | 欧美日韩不卡中文字幕在线 | 亚洲综合网在线观看首页 | 国产免费青青青免费视频观看 | 成人永久福利在线观看不卡 |